Here is a little information about our build in point form.

  •     ICF (insulated Concrete forms) construction to the trusses
  •     2 lb spray foam in attic
  •     R-34 Insulation in basement walls & R-10 under the slab
  •     Triple pane windows throughout
  •     HRV system with whole house HEPA filtration
  •     Waste water heat recovery system
  •     High efficiency wood burning fireplace with ducting to other parts of the house
  •     Reduced thermal bridging, air tight construction (.66 pre drywall blower door test)
  •     Energy efficient appliances, low and dual flush toilets
  •     Air chamber in the back entrance (most often used entrance in the house)
  •     10 radiant zones  using Warmboard and in slab heating
  •     95.2% AFUL efficient Viessmann condensing boiler
  •     non-combustible exterior finish.  Stone / Hardie plank/panel

Leave a Reply